3M™ Flat Fold Particulate Respirator & Surgical Mask 1870+ NIOSH

N95/P2 with Fluid Resistance, 20/Box

The 1870 healthcare respirator is designed to help provide respiratory protection for the wearer against certain airborne particles. It meets CDC guidelines for Mycobacterium tuberculosis exposure control. As a disposable particulate respirator, it is intended to reduce wearer exposure to certain airborne particles including those generated by electrocautery, laser surgery, and other powered medical instruments. As a surgical mask, it is designed to be fluid resistant to splash and spatter of blood and other infectious materials.

The 1870 particulate respirator is a personal protective equipment (PPE) that is primarily intended to protect the health care workers by reducing exposure to harmful airborne particles which are small enough to be inhaled – typically particles less than 100 microns in size. These include airborne particles that may contain biological material e.g. Bacillus anthracis, Mycobacterium tuberculosis, mould and the virus that causes Severe Acute Respiratory Syndrome (SARS), and Influenza. • Packaging: 20 respirators / box, 12 [Change to 12 Boxes/Case as per marketer] boxes / case Proper selection, training and use are essential in order for the respirator to adequately protect the wearer from certain airborne contaminants. Warning: Selection of the most appropriate Respiratory Protective Equipment (RPE) will depend on the particular situation and should be made only by a competent person knowledgeable of the actual working conditions and the limitations of RPE. Details regarding performance and limitations are set out on the respirator packaging and user instructions. Before using any respirator, the wearer must read and understand the user instructions for the product. Use in accordance with AS/NZS 1715:2009 Standard. Misuse can result in sickness or death. For more information, see your Supervisor or contact an Occupational Hygienist, Safety professional or 3M TechAssist Helpline – Australia 1800 024 464 / New Zealand 0800 364 357.

  • NIOSH certified N95
  • Meets CDC guidelines for Mycobacterium tuberculosis exposure control
  • Bacterial Filtration Efficiency (BFE) > 99% according to ASTM F2101
  • Fluid resistant according to ASTM F1862 at 160 mm Hg
  • Respirator contains no components made from natural rubber latex
  • Red coloured head straps for health care use
  • Mould nose clip to wearer’s nose shape to help reduce eyewear fogging and ensure a better seal and fit
  • For sale to healthcare professionals only

    Nano-Tech FFP2/P2 Particulate Respirator, Four-layers, Individually Packaged – 50Pack

    ≥99.66% Particle Filtration Efficiency (PFE) ≥99.92% Bacterial Filtration Efficiency (BFE) 

    • Australian Made • Cutting-edge nanofibre filters • Four-layers with elastic ear loops • Innovative three panel design improves fit and aesthetic and minimises gaps • High breathability • Soft, lightweight, comfortable & odourless • Individually packed • Latex free

    The first P2 mask manufactured in Australia and the only one utilising nano-fibre technologyfor superior protection, breathability and comfort.

    NANO-TECH FFP2/P2 Particulate Respirator feature advanced filtering and design details that allow them to be worn comfortably for extended periods of time while maintaining their class-leading functionality over standard melt blown filter respirators.
    AMD’s NANO-TECH P2 Particulate Respirators feature advanced filtering and design details that allow them to be worn comfortably for extended periods of time while maintaining their class-leading functionality over standard melt blown filter respirators. Cutting-edge nanofibre filters of the P2 respirator mask are incorporated into a face-contouring design that creates an effective barrier against potentially harmful airborne particles and aerosols such as dust, virus, and bacteria as well as infectious liquid materials such as blood and fluids. Nanofibre technology ensures excellent breathability and lightness even with the assurance of four protective layers.
    Technology: Nano-filters, comprised of nanofibres, deliver higher filtration efficiency than standard melt brown filters and are lighter and more breathable. A particulate respirator also maintains its functionality after exposure to moisture while typical filters lose their electrostatic properties once exposed to water. AMD’s nano-filters are water-resistant and protective against airborne particles, aerosols, and liquid.
    Fit: Respirator P2 mask features an innovative three-panel design that fits naturally around the nose and mouth creating a better seal and aesthetic. Elastic ear loops hold the particulate respirator securely in place. A soft inner layer and moldable padded nose bridge wire provide extra comfort.
    Comfort: Nano-filter respirators are lighter than standard respirators and allow enhanced breathability which allows them to be worn for hours. The three-panel design of the P2 respirator mask unfolds to shape naturally around the face maximising ventilation around the nose and mouth while still maintaining an effective seal to the environment. Nano-filter respirators are potentially viable options for populations with breathing restrictions such as the elderly and those with heart and lung conditions.
    Packaging: Each nano-filter particulate respirator is individually packaged for hygiene and designed to fold flat to facilitate portability and storage. Individual wrapping makes it convenient to carry and distribute without contamination. 50/Box.
    DIRECTIONS
    1. Before putting on the respirator P2 mask, wash hands for at least 20 seconds with soap and water or rub hands together thoroughly with alcohol-based hand sanitiser.
    2. Take care not to touch the inside layer of the P2 respirator that will be in contact with the nose and mouth when unpacking and while donning.
    3. Check for defects in the face respirator such as tears or broken loops.
    4. Position the label side of the P2 respirator outward and orient the respirator so that the foam nose bridge strip is at the top.
    5. Unfold the respirator P2 mask while holding onto the edges (again being careful not to touch the area that will be in contact with the nose and mouth). Position the unfolded respirator over the nose and mouth and place one earloop over each ear.
    6. Mould the nose bridge wire to the bridge of the nose and while pinching the nose bridge in place stretch the bottom of the respirator to over the chin. Press along the edges of the respirator to maximise the seal.
    • Avoid touching the respirator while using it; if touched, clean hands with alcohol-based hand sanitiser or soap and water.
    • Replace P2 respirator if it becomes obviously contaminated; never reuse single-use respirators.
    Removing the respirator Wash hands with soap and water or alcohol-based hand sanitiser before removing the respirator. Remove the P2 respirator by unhooking the ear loops, taking care not to touch the front of the respirator which might have become contaminated. Discard immediately in a closed bin and clean hands with alcohol-based hand sanitiser or soap and water.

    WARNING

    Selection of the most appropriate Respiratory Protective Equipment (RPE) will depend on the particular situation and should be made only by a competent person knowledgeable of the actual working conditions and the limitations of the RPE. Details regarding performance and limitations are specified on the respirator packaging and user instructions. Before using any respirator, the wearer must read and understand the user instructions for the product. Use in accordance with AS/NZS 1716:2012 Standard. Misuse can result in sickness or death. For more information, consult a supervisor or contact an Occupational Hygienist and Safety professional.
    Manufacturer: https://amdmed.com.au Number per Box: 50
    Certification/Class P2
    Filter performance ≥ 94%
    Test agent NaCl
    Flow rate 95 L/min
    Total inward leakage (TIL) ≤ 8% leakage
    Inhalation resistance ≤ 70 Pa (at 30L/min)≤ 240 Pa (at 95L/min)
    Flow rate Varied – see above
    Exhalation resistance ≤ 120 Pa
    Flow rate 85L/min
    Exhalation valve leakage requirement Leak rate ≤ 30mL/min
    Force applied -250 Pa
    CO2 clearance requirement ≤ 1%
    WORLD STANDARDS AND CLASSIFICATIONDisposable respirator mask, are subject to various regulatory standards around the world. These standards specify certain required physical properties and performance characteristics in order for respirators to claim compliance. During a pandemic, health authorities will often use the following performance standards when making respirator recommendations, * P2 (Australia/New Zealand AS/NZS 1716:2012) Respiratory protective devices describes three classes of particulate filter, Class P1, P2 and P3. The P2 respirator is equivalent to the USA standard N95 and endorsed by the Australian government for public use during the corona virus pandemic. * N95 (United States NIOSH-42CFR84) * FFP2 (Europe EN 149-2001) * KN95 (China GB2626-2006) * Korea 1st class (Korea KMOEL – 2017-64) * DS2 (Japan JMHLW-Notification 214, 2018) A P2 FACE MASK YOU CAN TRUST Our 100% Australian made P2 certified face mask has gone through the rigorous testing and compliance framework so that you have the peace of mind of knowing you are wearing a mask of the highest quality and standard. – CE Certified CE marking is a certification mark that indicates conformity with health, safety, and environmental protection standards for products sold within the European Economic Area Certified FFP2 (EN 149:2001) – BSI Benchmark Certified The Benchmark Certification recognises that a supplier of goods has in place a management system that meets the requirements of Benchmark standards, which were established to give customers confidence. – JAS-ANZ Certified The Joint Accreditation System of Australia and New Zealand (JAS-ANZ) helps to provide accreditation for products and services. P2 (Australia/New Zealand AS/NZS 1716:2012) – International Medical Device Certified Our quality management system is certified to ISO 13485 international medical device standards ensuring the safety and effectiveness of our mask. Social distancing is still the number 1 option, but if you are in a place or situation which does not allow you to social distance, then the P2 face mask will provide you and your family with the added protection during these sensitive pandemic times.